کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1254205 | 971359 | 2014 | 4 صفحه PDF | دانلود رایگان |
A method was developed for the determination of tetraethyl ammonium (TEA) by reversed-phase ion-pair chromatography with indirect ultraviolet detection. Chromatographic separation was achieved on a reversed-phase C18 column using background ultraviolet absorbing reagent – ion-pair reagent – organic solvent as mobile phase. The effects of the background ultraviolet absorbing reagents, detection wavelength, ion-pair reagents, organic solvents and column temperature on the determination method were investigated and the retention rules discussed. Results found that TEA could be successfully analyzed by using 0.7 mmol/L 4-aminophenol hydrochloride and 0.15 mmol/L 1-heptanesulfonic acid sodium mixed with 20% (v/v) methanol as mobile phase at a UV detection wavelength of 230 nm. Under these conditions, the retention time of tetraethyl ammonium was 2.85 min. The detection limit (S/N = 3) for TEA was 0.06 mg/L. The relative standard deviations (n = 5) for peak area and retention time were 0.35% and 0.02%, respectively. The method has been successfully applied to the determination of synthesized tetraethyl ammonium bromide. Recovery of tetraethyl ammonium after spiking was 99.1%.
Utilizing 4-aminophenol hydrochloride as background ultraviolet absorbing reagent, the determination of tetraethyl ammonium is achieved by ion-pair chromatography with indirect ultraviolet detection.Figure optionsDownload as PowerPoint slide
Journal: Chinese Chemical Letters - Volume 25, Issue 2, February 2014, Pages 201–204