کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1266724 972294 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
New flowmetric measurement methods of power dissipated by an ultrasonic generator in an aqueous medium
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
New flowmetric measurement methods of power dissipated by an ultrasonic generator in an aqueous medium
چکیده انگلیسی

Two new determination methods of the power dissipated in an aqueous medium by an ultrasound generator were developed. They are based on the use of a heat flow sensor inserted between a tank and a heat sink that allows to measure the power directly coming through the sensor. To be exploitable, the first method requires waiting for stationary flow. On the other hand, the second, extrapolated from the first one, makes it possible to determine the dissipated power in only five minutes. Finally, the results obtained with the flowmetric method are compared to the classical calorimetric ones.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasonics Sonochemistry - Volume 14, Issue 2, February 2007, Pages 99–106
نویسندگان
, ,