کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1267270 1496929 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Electrochemical sensor for the sensitive determination of norfloxacin in human urine and pharmaceuticals
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Electrochemical sensor for the sensitive determination of norfloxacin in human urine and pharmaceuticals
چکیده انگلیسی

Electrochemical determination of Norfloxacin (NF) has been presented at edge plane (EPPGS) and basal plane pyrolytic graphite sensors (BPPGS) by using square wave voltammetry at physiological pH 7.2. An increased peak current with a shift of peak potential to less positive value was observed at EPPGS as compared to BPPGS. The effect of pH, scan rate and analyte concentration has been examined. The peak current was found to be linear to the concentration of NF in the range 0.5 × 10− 6 to 50.0 × 10− 6 mol L− 1 for EPPGS and the detection limit (3σ/b) was found to be 28.3 × 10− 8 mol L− 1. The method has been successfully used to determine the content of NF in the pharmaceutical preparations. Biological relevance of the developed method has been described by the determination of NF in human urine samples of the patients undergoing treatment with NF. The method is selective and NF can be determined without any interference from common urine metabolites such as uric acid and ascorbic acid.


► The norflox, used for the treatment of various infections has been determined.
► The edge plane pyrolytic graphite sensor has been used.
► A low detection limit has been achieved.
► The practical application of the developed method is demonstrated in human urine.
► Common metabolites such as uric acid, ascorbic acid did not interfere.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Bioelectrochemistry - Volume 83, February 2012, Pages 46–51
نویسندگان
, , ,