عنوان انگلیسی مقاله ISI
Theoretical and experimental estimation of limiting input heat flux for thermoelectric power generators with passive cooling
ترجمه فارسی عنوان
برآورد نظری و تجربی محدود کردن جریان شار حرارتی برای ژنراتورهای ترموالکتریک با خنک کننده منفعل
کلمات کلیدی
محدود کردن شار حرارتی، گرمازدایی متعارف، ژنراتور ترموالکتریک، گرما غیر فعال،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
This paper focuses on theoretical and experimental analysis used to establish the limiting heat flux for passively cooled thermoelectric generators (TEG). 2 commercially available TEG's further referred as type A and type B with different allowable hot side temperatures (150 °C and 250 °C respectively) were investigated in this research. The thermal resistance of TEG was experimentally verified against the manufacturer's specifications and used for theoretical analysis in this paper. A theoretical model is presented to determine the maximum theoretical heat flux capacity of both the TEG's. The conventional methods are used for cooling of TEG's and actual limiting heat flux is experimentally established for various cold end cooling configurations namely bare plate, finned block and heat pipe with finned condenser. Experiments were performed on an indoor setup and outdoor setup to validate the results from the theoretical model. The outdoor test setup consist of a fresnel lens solar concentrator with manual two axis solar tracking system for varying the heat flux, whereas the indoor setup uses electric heating elements to vary the heat flux and a low speed wind tunnel blows the ambient air past the device to simulate the outdoor breezes. It was observed that bare plate cooling can achieve a maximum heat flux of 18,125 W/m2 for type A and 31,195 W/m2 for type B at ambient wind speed of 5 m/s while maintaining respective allowable temperature over the hot side of TEG's. Fin geometry was optimised for the finned block cooling by using the fin length and fin gap optimisation model presented in this paper. It was observed that an optimum finned block cooling arrangement can reach a maximum heat flux of 26,067 W/m2 for type A and 52,251 W/m2 for type B TEG at ambient wind speed of 5 m/s of ambient wind speed. The heat pipe with finned condenser used for cooling can reach 40,375 W/m2 for type A TEG and 76,781 W/m2 for type B TEG.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Solar Energy - Volume 111, January 2015, Pages 201-217
نویسندگان
, , , , ,