کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1552290 998185 2007 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of the thermal performance and comfort conditions produced by five different passive solar heating strategies in the United States midwest
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Analysis of the thermal performance and comfort conditions produced by five different passive solar heating strategies in the United States midwest
چکیده انگلیسی

This paper presents a summary of the thermal performance of five different passive solar test-cells (Direct Gain, Trombe-wall, Water-wall, Sunspace, and Roofpond) and a control test-cell during the 2002–2003 heating season in Muncie, Indiana. The results discussed in this article correspond to the initial phase of a longer study (data were collected from December of 2002 until August of 2004). The project’s original intent was to identify any barriers to achieving thermal comfort within a space when passive solar heating systems are employed in severe winter climates with predominant overcast sky conditions. Because of the original intent of this project, the test-cells were arranged with their smaller facades oriented to the north and south and the longer facades facing east and west. This arrangement permitted to study temperature differences throughout the day (diurnal operative temperature swings) and also simultaneous temperature differences throughout the space (a simultaneous comparison of four points instrumented within each cell to detect variations between the south side and the north side of the test-cells).The results of this phase of the study show that the Direct Gain strategy had the largest diurnal variations of temperature with an average operative temperature swing of 7.8 °C and a maximum variation during the reported period of 10.3 °C. By contrast, the Roofpond strategy had the smallest diurnal variations of temperature with an average operative temperature swing of 1.2 °C and a maximum variation during the reported period of 1.4 °C. In terms of the simultaneous variations in the operative temperature between the south side and the north side of the test-cells, the Direct Gain strategy showed again the highest variations with an average simultaneous operative temperature difference between the south and north sides of the test-cell of 2.9 °C and a maximum variation during the reported period of 3.7 °C. The Roofpond strategy, on the other hand, had the smallest variations with an average simultaneous operative temperature difference between the south and north sides of the test-cell of 0.1 °C and a maximum variation during the reported period of 0.2 °C. The conclusions of this study demonstrate that diurnal variations of the operative temperature are primarily determined by the type of passive solar strategy utilized (with direct gain producing the highest temperature swings and the indirect gain strategies producing the smallest temperature swings) and by the thermal storage capacity of the system (with a higher thermal storage producing a smaller temperature swing). The simultaneous variations of the operative temperature inside the test-cells during the daytime were mostly influenced by the type of passive solar strategy utilized (with direct gain producing the highest simultaneous differences in temperature between the south and north sides of the test-cell and the indirect gain strategies producing the smallest temperature swings).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Solar Energy - Volume 81, Issue 5, May 2007, Pages 581–593
نویسندگان
,