کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
155581 456902 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simulation of aromatics extraction with an ionic liquid in a pilot-plant Kühni extractor based on single-drop experiments
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Simulation of aromatics extraction with an ionic liquid in a pilot-plant Kühni extractor based on single-drop experiments
چکیده انگلیسی

Pilot-plant experiments in a Kühni extractor for the extraction of toluene from a heptane+toluene mixture by means of the ionic liquid [3-mebupy][DCA] were performed. Previous work (Meindersma et al., 2010, 2012) has shown that [3-mebupy][DCA] is a promising solvent for the extraction of aromatic substances such as toluene. An alternative approach to performing time and material consuming pilot-plant experiments is modelling with the drop population-balance model ReDrop. Models in the ReDrop program accounting for different phenomena, such as drop sedimentation, drop breakage and coalescence as well as mass transfer, contain liquid-liquid system specific parameters that are fitted to lab-scale experiments with single drops. A single-drop sedimentation experiment with heptane (c)+toluene+[3-mebupy][DCA] (d) was performed and the parameters of the sedimentation model fitted to the experimental data. Models accounting for the hindrance of drop sedimentation due to column internals and models for drop breakage were taken from the literature. On this basis, the Kühni extractor was then simulated with ReDrop. Hydrodynamic parameters such as hold-up and Sauter mean diameter are in good agreement with the experimental data. Also the mass-transfer performance of the [3-mebupy][DCA] in combination with the Kühni extractor was modeled with good accuracy. It was shown that the ReDrop concept is a promising alternative to pilot-plant experiments in terms of need of materials and time to evaluate new ILs for their usability in extraction columns.


► Pilot-plant experiments in a Kühni column were performed with the IL [3-mebupy][DCA].
► [3-mebupy][DCA] is a promising solvent for extraction of toluene from heptane.
► Single-drop experiments were performed with ionic liquid as the dispersed phase.
► Accurate column simulation with “ReDrop” possible based on single-drop experiments.
► Method is promising to quickly evaluate new ILs for usability in extraction columns.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemical Engineering Science - Volume 82, 12 September 2012, Pages 167–176
نویسندگان
, , , , ,