کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1579876 | 1001233 | 2010 | 5 صفحه PDF | دانلود رایگان |

The susceptibility to hydrogen induced cracking (HIC) was evaluated for X120 steels containing different amounts of Mn and Al in a H2S environment. The hydrogen trapping efficiency was investigated by measuring the permeability (J∞L) and the apparent diffusivity (Dapp). The results demonstrated that larger amount of the inclusions, and larger area and volume fraction of the inclusions make steels more susceptible to HIC. The steel with a microstructure consisting of granular bainite and M/A (martensite/austenite) microconstituents is more susceptible to HIC. The ability of the microstructure and the inclusions to trap hydrogen was explained in terms of the apparent diffusivity (Dapp), permeability (J∞L), and solubility of hydrogen in steels (capp). The lower the values of Dapp and J∞L and the higher the value of capp are, the more the hydrogen trapping occurs in the steel, and the more the steel is susceptible to HIC.
Research highlights▶ Increasing in the amount, the area and the volume fraction of the inclusion in steel makes the steel more susceptible to HIC. ▶ The steel with a microstructure consisting of granular bainite and M/A (Martensite/austenite) microconstituents is more susceptible to HIC. ▶ The lower the values of Dapp and J∞L and the higher the value of capp are the more the hydrogen trapping occurs in the steel, and the more the steel is susceptible to HIC.
Journal: Materials Science and Engineering: A - Volume 527, Issue 26, 15 October 2010, Pages 6997–7001