Corrosion behavior of extrusion-drawn pure Mg wire immersed in simulated body fluid
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد فلزات و آلیاژها
پیش نمایش صفحه اول مقاله
Corrosion behavior of extrusion-drawn pure Mg wire immersed in simulated body fluid
چکیده انگلیسی

The corrosion behaviors of extrusion-drawn pure magnesium wire soaked in simulated body fluid (SBF) and 0.9% NaCl solution were studied. The corrosion law of the pure magnesium wire immersed in SBF was investigated by measuring the average corrosion rate and the pH values of the solution after corrosion. It is found that the corrosion mechanism of the pure magnesium wire was pitting after the observation of corrupted surface morphology by scanning electron microscopy (SEM). Moreover, the corrosion law of extrusion-drawing pure magnesium wire in 0.9% NaCl solution implied that the smaller the grain size of the wire is, the better the corrosion resistance exhibits.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Transactions of Nonferrous Metals Society of China - Volume 21, Supplement 2, August 2011, Pages s258-s261