کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1689468 1011229 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cold leak tests of LHC beam screens
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد سطوح، پوشش‌ها و فیلم‌ها
پیش نمایش صفحه اول مقاله
Cold leak tests of LHC beam screens
چکیده انگلیسی

In order to guide the high energy proton beams inside its two 27 km long vacuum rings, the Large Hadron Collider (LHC) at CERN, Geneva, makes use of superconducting technology to create the required magnetic fields. More than 4000 beam screens, cooled at 7–20 K, are inserted inside the 1.9 K beam vacuum tubes to intercept beam-induced heat loads and to provide dynamic vacuum stability. As extremely high helium leak tightness is required, all beam screens have been leak tested under cold conditions in a dedicated test stand prior to their installation. After describing the beam screen design and its functions, this report focuses on the cold leak test sequence and discusses the results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Vacuum - Volume 84, Issue 1, 25 August 2009, Pages 293–297
نویسندگان
, , , ,