کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1722968 1014750 2006 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
On necessity of placing an aerator in the bottom discharge tunnel at the Longtan Hydropower Station1
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی دریا (اقیانوس)
پیش نمایش صفحه اول مقاله
On necessity of placing an aerator in the bottom discharge tunnel at the Longtan Hydropower Station1
چکیده انگلیسی

The air entrainment for avoiding cavitation damage has been widely used in long free flow tunnels. It is crucial to determine whether an aerator is needed for shorter tunnels. In this article, the bottom discharge tunnel at the Longtan Hydropower Station was involved, for which the free flow tunnel section was only 50.00 m long. The cavitation in the tunnel with and without the aerator was investigated using the physical models of the scale 1/30, through the measurements of cavitation noise. The experimental results show that it is necessary to place the aerator at the inlet of the free flow section for higher reservoir level to protect this tunnel from cavitation damage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hydrodynamics, Ser. B - Volume 18, Issue 6, December 2006, Pages 698-701