کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1784777 1023277 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quantitative determination of subsurface defects in a reference specimen made of Plexiglas by means of lock-in and pulse phase infrared thermography
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک اتمی و مولکولی و اپتیک
پیش نمایش صفحه اول مقاله
Quantitative determination of subsurface defects in a reference specimen made of Plexiglas by means of lock-in and pulse phase infrared thermography
چکیده انگلیسی

Lock-in and pulse phase infrared thermography measurement techniques have been exploited for quantitative assessment of subsurface defects in a reference specimen made of Plexiglas. Radiometric thermal images were post-processed using a contrast approach in the frequency domain, allowing defect depth to be resolved with a combined standard uncertainty of about 5% for thicknesses up to 3.6 mm. Conversely, significant radial heat diffusion next to the boundary of the discontinuities made accurate sizing of deeper subsurface defects more difficult, resulting in a combined standard uncertainty of about 17% for a 10 mm diameter flat-bottomed hole of 3.6 mm deep. The obtained results demonstrate the potentiality of active thermography as a fast, powerful contactless NDE measurement tool.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Infrared Physics & Technology - Volume 53, Issue 5, September 2010, Pages 363–371
نویسندگان
,