Short T2 tissue imaging with the Pointwise Encoding Time reduction with Radial Acquisition (PETRA) sequence: The additional value of fat saturation and subtraction in the meniscus
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک ماده چگال
پیش نمایش صفحه اول مقاله
Short T2 tissue imaging with the Pointwise Encoding Time reduction with Radial Acquisition (PETRA) sequence: The additional value of fat saturation and subtraction in the meniscus
چکیده انگلیسی

PurposeThe purposes of this study were (1) to compare single-echo PETRA with dual-echo PETRA using in vivo MR imaging, (2) to compare non-fat-saturated PETRA with fat-saturated PETRA using a 3-T clinical MR scanner, and (3) to determine the effect of the adequate sequence and post-processing method.Materials and methodsTwenty-two patients underwent dual-echo 3D PETRA sequence knee MR imagining (TE of 70 μs and 2.3 ms) with and without fat-saturation using a 3 T clinical MR scanner (Magnetom Trio, Siemens, Erlangen, Germany). The study population was classified into two groups: (1) normal meniscus on conventional MR images with no related physical examination on medical records and (2) meniscal degeneration or tear. We reformatted four image sets: (1) ultrashort TE signal without fat-saturation, (2) ultrashort TE signal with fat-saturation, (3) weighted-subtraction image of dual-echo PETRA images without fat-saturation, and (4) weighted-subtraction image with fat-saturation. For the weighted-subtraction images, the ultrashort TE image was rescaled relative to the second echo image with weighting factors from 0.6 based on SNR and CNR analyses. For quantitative assessment, the mean signal intensities inside user-drawn regions of interest (ROIs) were drawn and recorded. For statistical analyses, the t-test was used to compare the two groups and effect size was used for comparison of the discrimination power.ResultsIn all image sets, the mean signal intensity values were lower in patients with meniscal degeneration/tear compared to controls on both fat-saturated and non-fat-saturated MR images. The single-echo ultrashort TE images showed higher effect sizes than the weighted-subtraction image of dual-echo images.ConclusionWe demonstrated that there was significantly lower signal intensity on ultrashort TE PETRA images in the patients with meniscal pathologies. In addition, the single-echo of the ultrashort TE PETRA images echo time could be a more sensitive indicator between normal and pathologic meniscus conditions in patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Magnetic Resonance Imaging - Volume 33, Issue 4, May 2015, Pages 385–389
نویسندگان
, , ,