کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1807975 1025300 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک ماده چگال
پیش نمایش صفحه اول مقاله
How does distortion correction correlate with anisotropic indices? A diffusion tensor imaging study
چکیده انگلیسی

PurposeThe purpose of this study was to determine a suitable registration algorithm for diffusion tensor imaging (DTI) using conventional preprocessing tools [statistical parametric mapping (SPM) and automated image registration (AIR)] and to investigate how anisotropic indices for clinical assessments are affected by these distortion corrections.Materials and MethodsBrain DTI data from 15 normal healthy volunteers were used to evaluate four spatial registration schemes within subjects to correct image distortions: noncorrection, SPM-based affine registration, AIR-based affine registration and AIR-based nonlinear polynomial warping. The performance of each distortion correction was assessed using: (a) quantitative parameters: tensor-fitting error (Ef), mean dispersion index (MDI), mean fractional anisotropy (MFA) and mean variance (MV) within 11 regions of interest (ROI) defined from homogeneous fiber bundles; and (b) fiber tractography through the uncinate fasciculus and the corpus callosum. Fractional anisotropy (FA) and mean diffusivity (MD) were calculated to demonstrate the effects of distortion correction. Repeated-measures analysis of variance was used to investigate differences among the four registration paradigms.ResultsAIR-based nonlinear registration showed the best performance for reducing image distortions with respect to smaller Ef (P<.02), MDI (P<.01) and MV (P<.01) with larger MFA (P<.01). FA was decreased to correct distortions (P<.0001) whether the applied registration was linear or nonlinear and was lowest after nonlinear correction (P<.001). No significant differences were found in MD.ConclusionIn conventional DTI processing, anisotropic indices of FA can be misestimated by noncorrection or inappropriate distortion correction, which leads to an erroneous increase in FA. AIR-based nonlinear distortion correction would be required for a more accurate measurement of this diffusion parameter.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Magnetic Resonance Imaging - Volume 24, Issue 10, December 2006, Pages 1369–1376
نویسندگان
, , , , , , , , , ,