کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1822426 1526342 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ruggedization of CdZnTe detectors and detector assemblies for radiation detection applications
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Ruggedization of CdZnTe detectors and detector assemblies for radiation detection applications
چکیده انگلیسی


• We developed ruggedization methods to enhance reliability of CZT detector assemblies.
• Attachment of CZT radiation detectors was improved through comparative studies.
• Bare detector metallization strength was evaluated through shear test and thermal cycling.
• Detector assemblies survived JEDEC temperature cycling from −30 to +65 °C for over 1000 cycles.
• Shock and vibration tests of detector assemblies passed ANSI N42.34-2006 standards.

This paper described improvements in the ruggedization of CdZnTe detectors and detector assemblies for use in radiation detection applications. Research included experimenting with various conductive and underfill adhesive material systems suitable for CZT substrates. A detector design with encapsulation patterning was developed to protect detector surfaces and to control spacing between CZT anode and PCB carrier. Robustness of bare detectors was evaluated through temperature cycling and metallization shear testing. Attachment processes using well-chosen adhesives and PCB carrier materials were optimized to improve reliability of detector assemblies, resulted in Improved Attachment Detector Assembly. These detector assemblies were subjected to aggressive temperature cycling, and varying levels of drop/shock and vibration, in accordance with modified JEDEC, ANSI and FedEx testing standards, to assess their ruggedness. Further enhanced detector assembly ruggedization methods were investigated involving adhesive conformal coating, potting and dam filling on detector assemblies, which resulted in the Enhanced Ruggedization Detector Assembly.Large numbers of CZT detectors and detector assemblies with 5 mm and 15 mm thick, over 200 in total, were tested. Their performance was evaluated by exposure to various radioactive sources using comprehensive predefined detector specifications and testing protocols. Detector assemblies from improved attachment and enhanced ruggedization showed stable performances during the harsh environmental condition tests. In conclusion, significant progress has been made in improving the reliability and enhancing the ruggedness of CZT detector assemblies for radiation detection applications deployed in operational environments.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 784, 1 June 2015, Pages 44–50
نویسندگان
, , , , ,