کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1823088 | 1526410 | 2013 | 7 صفحه PDF | دانلود رایگان |
• We studied light output of different shapes and size BGO crystals with an APD.
• With a Monte-Carlo simulation, we successfully reproduced measured light outputs of BGO.
• We derived a scaling law of a rectangle crystal volume and surface area APD attached.
• We measured a dependence of the light output on a position with non-rectangle crystal.
Light collection efficiency from BGO crystal scintillators of various sizes and shapes was measured by reading them using 1×1 cm2 avalanche photo diodes. When the crystals have simple geometry, the light collection efficiency was found to depend on their size, shape and the read-out position through a rather well-defined empirical scaling relation. The light collection efficiency of tapered crystals was seen to depend on both the position of γ-rayγ-ray irradiation, and the read-out position of the avalanche photo diodes. Using optical Monte-Carlo simulations, the relation was reproduced assuming plausible proper parameters for surface conditions and the attenuation length. This results were reproduced with a reasonable accuracy by optical Monte-Carlo simulations. Simple physical explanations are given to these geometrical effects.
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 715, 1 July 2013, Pages 105–111