چکیده انگلیسی

A new method to correct the emulsion deformation, mainly produced in the development process, is developed to recover the high accuracy of nuclear emulsion as a tracking device. The method is based on a precise photomask and a careful treatment of the emulsion films. A position measurement accuracy of 0.6μm is obtained over an area of 5 cm×7 cm. The method allows to measure positions of track segments with submicron accuracy in an ECC brick with as few as 10 reference tracks for alignment. Such a performance can be important for hybrid emulsion experiments at underground laboratories where only a small number of reference tracks for alignment are available.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 711, 21 May 2013, Pages 1–7