کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1823143 1526402 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The Timepix Telescope for high performance particle tracking
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
The Timepix Telescope for high performance particle tracking
چکیده انگلیسی

The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed around the dual capability of the Timepix ASICs to provide information about either the deposited charge or the timing information from tracks traversing the 14×14 mm matrix of 55×55μm pixels. The rate of reconstructed tracks available is optimised by taking advantage of the shutter driver readout architecture of the Timepix chip, operated with existing readout systems. Results of tests conducted in the SPS North Area beam facility at CERN show that the telescope typically provides reconstructed track rates during the beam spills of between 3.5 and 7.5 kHz, depending on beam conditions. The tracks are time stamped with 1 ns resolution with an efficiency of above 98% and provide a pointing resolution at the centre of the telescope of ∼1.6μm. By dropping the time stamping requirement the rate can be increased to ∼15kHz, at the expense of a small increase in background. The telescope infrastructure provides CO2 cooling and a flexible mechanical interface to the device under test, and has been used for a wide range of measurements during the 2011–2012 data taking campaigns.


• We provide a technical description of the Timepix Telescope for particle tracking applications.
• We demonstrate the spatial and timing resolution to be 2μm2μm and 1 ns respectively.
• The maximum particle rate is 7.5 kHz with highly resolved timing and spacing.
• The maximum particle rate is 15 kHz with only highly resolved spacing.
• We briefly describe the software and tracking algorithms used to achieve this.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 723, 21 September 2013, Pages 47–54
نویسندگان
, , , , , , , , , , , , , , , , , , , ,