کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1825272 | 1027358 | 2011 | 4 صفحه PDF | دانلود رایگان |

The Belle II detector operating at the future upgrade to the KEKB accelerator will perform high-statistics precision investigations into the flavor sector of the Standard Model. As charged hadron identification is a vital element of the experiment's success, the time-of-propagation (TOP) counter has been chosen as the primary particle identification device in the barrel region of Belle II. The TOP counter is a compact variant of the detection of internally reflected Cherenkov light (DIRC) technique and relies heavily on exquisite single photon timing resolution with micro-channel plate photomultiplier tubes. We discuss the general principles of TOP operation and optimization of the Belle II TOP configuration, which is expected to provide 4 sigma or better separation of kaons and pions up to momenta of approximately 4 GeV/c.
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 639, Issue 1, 21 May 2011, Pages 177–180