کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1825533 1027365 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC
چکیده انگلیسی

New developments in Thin Gap Chamber (TGC) detectors to provide fast trigger information and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 C/cm of wire, without showing any deterioration in their performance. Two large (1.2×0.8 m2) prototypes containing four gaps, each gap providing pad, strip and wire readout, with a total thickness of 50 mm, have been constructed. Their local spatial resolution has been measured in a 100 GeV/c   muon test beam at CERN. At perpendicular incidence angle, a single gap position resolution of better than 60μm has been obtained. For an incidence angle of 20° a resolution of less than 100μm was achieved. TGC prototypes were also tested under a flux of 105 Hz/cm2 of 5.5–6.5 MeV neutrons, showing a high efficiency for the detection of cosmic muons.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 628, Issue 1, 1 February 2011, Pages 177–181
نویسندگان
, , , , , , , , , , , , , , , ,