کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1826125 | 1526468 | 2010 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A 4Â V, ns-range pulse generator for the test of Cherenkov Telescopes readout electronics
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
ابزار دقیق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
We present in this paper the design, fabrication and verification of a ns-range pulse generator based on a Step Recovery Diode (SRD). This device needs only a 5Â V DC power supply, delivers 1Â ns pulses with peak amplitudes in excess of 4Â V and features state of the art jitter figures. In addition, the pulser contains a trigger channel. The long standing problem of the SRD simulation via circuital analysis is addressed. It is shown that the dynamic properties of the Step Recovery Diode can accurately be reproduced via a small signal circuital simulation for the rise times needed in a ns-range pulser. It is also demonstrated that strong inaccuracies in the pulse shape prediction are obtained if the wave propagation through the lines typically used in this type of circuits is simulated by a simple Transverse Electromagnetic Mode (TEM) line model. Instead, it is necessary to account for non-TEM effects. By means of broadband resistive power splitters and high dynamic range amplifiers, a prototype of 4 channels was also fabricated. This prototype is particularly useful for testing the readout electronics of Cherenkov Telescopes, but additional applications to other large-scale experiments are expected, any of those where calibration or verification with compact ns-range pulsers featuring low jitter, large dynamic ranges and multichannel operation is needed. In addition, the fabrication cost of this pulser is almost negligible as compared with bulky, commercially available waveform generators, which rarely deliver ns pulses in excess of 3Â V. Furthermore, the small size of the pulser presented here and its low power consumption allow an easy integration into more complex systems.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 620, Issues 2â3, 11â21 August 2010, Pages 456-461
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 620, Issues 2â3, 11â21 August 2010, Pages 456-461
نویسندگان
P. Antoranz, I. Vegas, J.M. Miranda,