کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1828887 1027442 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The HARP resistive plate chambers: Characteristics and physics performance
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
The HARP resistive plate chambers: Characteristics and physics performance
چکیده انگلیسی

The HARP resistive plate chamber (RPC) system was designed for time-of-flight measurement in the large-angle acceptance region of the HARP spectrometer. It comprised 46 four-gap glass RPCs covering an area of 8m2. The design of the RPCs, their operation, intrinsic properties, and system performance are described. The intrinsic time resolution of the RPCs is 127 ps leading to a system time-of-flight resolution of 175 ps. It is argued that gross differences between pion and proton timing in multi-gap timing RPCs, reported recently in the literature, do not exist.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 602, Issue 3, 1 May 2009, Pages 639–643
نویسندگان
, , , , , , , , , , , , , , , , , , ,