کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1829116 1526490 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and cooling of BESIII beryllium beam pipe
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Design and cooling of BESIII beryllium beam pipe
چکیده انگلیسی

The beryllium beam pipe was restructured according to the requirements of the upgraded BESIII (Beijing Spectrometer) experiment. SMO-1 (sparking machining oil no. 1) was selected as the coolant for the central beryllium beam pipe. The cooling gap width of the beryllium beam pipe was calculated, the influence of concentrated heat load on the wall temperature of the beryllium beam pipe was studied, and the optimal velocity of the SMO-1 in the gap was determined at the maximum heat load. A cooling system for the beam pipe was developed to control the outer wall temperature of the beam pipe. The cooling system is reported in this paper with regard to the following two aspects: the layouts and the automation. The performance of the cooling system was tested on the beam pipe model with trim size. The test results show that the design of the beryllium beam pipe is reasonable and that the cooling system achieves the BESIII experimental aim. The cooling system has already passed the acceptance test and has been installed in position. It will be put into practice for the BESIII experiment in 2008.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 585, Issues 1–2, 21 January 2008, Pages 40–47
نویسندگان
, , , ,