کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1829617 1027462 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of two methods for simulation of hard X-ray nanofocusing by elliptical mirrors
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Comparison of two methods for simulation of hard X-ray nanofocusing by elliptical mirrors
چکیده انگلیسی
Wave-optical calculations are essential for predicting the X-ray focusing performance of precisely figured elliptical mirrors. The complex wavefield in the vicinity of the focal plane of a mirror with RMS height error in the nanometer range compared to the best-fit ellipse has been calculated using two methods. A pupil function method that treats the surface topography of a mirror as an aberration to a perfect ellipse was used to obtain the reflected amplitude and phase around the focal point downstream. The results were compared with direct propagation of waves from a point source, and it was found that both methods were in good agreement. Each approach provides advantages that are useful in designing mirrors to achieve diffraction limited focusing.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 582, Issue 1, 11 November 2007, Pages 138-141