Resolution studies on 5 GeV electron tracks observed with triple-GEM and MediPix2/TimePix-readout
چکیده انگلیسی

This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack is joined with a TimePix and MediPix2 chip (pixel size of 55×55μm2) and its readout properties are investigated with 5 GeV electrons. The spatial resolution of reconstructed cluster centers is determined as a function of the drift distance for different gases and stack configurations. Also the drift velocities are extracted. A single point resolution down to ≈25μm is achieved for small drift distances.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 581, Issues 1–2, 21 October 2007, Pages 274–278
نویسندگان
, , , , , , ,