کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1830205 | 1526492 | 2007 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Measurement of neutron response function for thin plastic scintillators using white neutron source from d–D breakup reaction
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
ابزار دقیق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The neutron response function for thin plastic scintillators has been measured using the white neutron source produced by the d–D breakup reaction. Deuteron energies of 9, 12 and 14 MeV were chosen to produce the neutron energy range from 0.5 to 17 MeV. The intensity of the neutron beam was measured by a well-calibrated BC-501A liquid scintillation detector at 0∘0∘. The measured results were compared with Monte Carlo simulations and verified by additional experiments at a neutron generator and the 2×1.7MV 5SDH-2 tandem accelerator. The results obtained from these experiments all agree well with the simulations.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 583, Issues 2–3, 21 December 2007, Pages 426–431
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 583, Issues 2–3, 21 December 2007, Pages 426–431
نویسندگان
Guoguang Zhang, Xichao Ruan, Xia Li, Jianfu Zhang, Jiwen Song, Xianpeng Zhang, Xiaodong Zhang, Dahai Li, Liang Chen, Hongbo Pan, Jing Jiang, Qiping Zhong, Hanxiong Huang, Long Hou, Zuying Zhou,