کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1830249 | 1027475 | 2008 | 4 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
TOPIX: The first prototype of pixel readout for PANDA experiment
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
ابزار دقیق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The first prototype (TOPIX) of pixel readout has been designed and tested in a first attempt to develop a custom solution for the pixel detector of the PANDA experiment. A small circuit composed of 32 single pixel readout cells was implemented in a 130Â nm CMOS process. Each cell is equipped with a preamplifier and a comparator circuit to measure the Time over Threshold (ToT). Several chips were characterized to check the uniformity of the preamplifier response and ToT signal. Total Ionizing Dose (TID) tests at different dose rate and displacement damage test were performed: the results of these measurements are reported in this paper.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 596, Issue 1, 21 October 2008, Pages 96-99
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 596, Issue 1, 21 October 2008, Pages 96-99
نویسندگان
D. Calvo, P. De Remigis, S. Martoiu, A. Rivetti, R. Wheadon,