کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1831103 1027491 2007 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule
چکیده انگلیسی

A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron Source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 575, Issue 3, 1 June 2007, Pages 456–460
نویسندگان
, , ,