Next generation of pnCCDs for X-ray spectroscopy and imaging
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
ابزار دقیق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
A special type of charge-coupled device, the pnCCD, has been developed in the nineties as focal-plane detector for the X-ray astronomy mission XMM-Newton of the European Space Agency. The pnCCD detector has been in operation since the satellite launch in 1999. It is performing up to date spectroscopy of X-rays in combination with imaging and high time resolution. The excellent performance of the flight camera is still maintained; in particular, the energy resolution has been nearly constant since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. The 'frame store pnCCD' shows various optimizations in device design and fabrication process. Devices with up to 256Ã512 pixels have been fabricated in 2004 and recently tested. Simultaneously, a programmable analog signal processor for the readout of the CCD signals, the DUO CAMEX, has been developed. The readout noise of the new detector has a value of 2 electrons ENC which is less than half of the figure of the XMM-Newton pnCCD. We measured an energy resolution that is close to the theoretical limit given by the Fano noise. In particular the low-energy response of the new devices was substantially improved. The quantum efficiency for X-rays is at least 90% in the entire energy band from 0.3 keV up to 11 keV. This is due to the ultra-thin photon entrance window as well as the full depletion of the 450 μm thick back-illuminated pnCCD. The position resolution is better than the pixel sizes of 75 μmÃ75 μm or 51 μmÃ51 μm because the signal charge is spread over up to four pixels which allows a more accurate event position determination. 'Out of time' events are substantially reduced to the order of 0.1% by operating the pnCCD in frame store mode. Higher operating temperatures, e.g. â20 °C, are possible due to the smaller thermally generated dark-current level of the new devices and the operation at higher frame rates. Low power consumption applications like for the ROSITA X-ray astronomy mission with low frame rates of, e.g. 20 images/s, as well as high frame rate applications, e.g. 200 images/s, are possible with the same device.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 568, Issue 1, 30 November 2006, Pages 141-148
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 568, Issue 1, 30 November 2006, Pages 141-148
نویسندگان
Norbert Meidinger, Robert Andritschke, Olaf Hälker, Robert Hartmann, Sven Herrmann, Peter Holl, Gerhard Lutz, Nils Kimmel, Gerhard Schaller, Martina Schnecke, Florian Schopper, Heike Soltau, Lothar Strüder,