کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1883533 1533415 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Measurement of rectum dose by in vivo alanine/ESR dosimetry in gynecological 192Ir HDR brachytherapy
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Measurement of rectum dose by in vivo alanine/ESR dosimetry in gynecological 192Ir HDR brachytherapy
چکیده انگلیسی


• ESR spectroscopy using alanine was used for HDR BT dosimetry.
• The studies were conducted in phantom and in vivo.
• The aim was to verify if the dose in rectum complies with ICRU Report 38 recommendations.
• Only 1 of the 10 patients presented a rectum dose above the recommended level.

High dose rate (HDR) brachytherapy (BT) used in treatments of gynecological cancer often results in high doses in the pelvic organs at risk (OARs) and the complications in the rectum are a serious concern. Dosimetry procedures in vivo can be used as an evaluation method of calculated dose in treatment planning. One dosimetric method is the use of alanine with electron spin resonance (ESR) that has been used in different clinical practices. The aim of this study was to indicate the dose level in the female rectum volume, using alanine dosimeters during 192Ir HDR gynecological BT, for cervical cancer. Doses were compared with the values obtained using the computational treatment planning system based on two orthogonal radiographic images. Firstly a phantom study in water was performed, enabling the in vivo study. Ten patients had the dose in rectum measured, resulting from 10 points properly referred; variations found were in the range of +60% and −50% of the delivered doses compared to the treatment planning system. Differences between planned and measured doses can be mainly due to uncertainty of dosimeter position determination, averaging of dose points specified over the whole dosimeter position, uncontrolled changes in detector position during treatment due to rectum movement and to a simplified treatment system planning, that do not take into account the details of the patient anatomy and the difference among the tissues. Results show that improvements of the protocol treatment should be done to enhance the relation between treatment planning system and experimental results, nevertheless the dose at the OARs was lower than the recommended by the ICRU Report 38.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 75, April 2015, Pages 45–52
نویسندگان
, , , , , ,