Review of the dose-to-water energy dependence of alanine and lithium formate EPR dosimeters and LiF TL-dosimeters – Comparison with Monte Carlo simulations
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Review of the dose-to-water energy dependence of alanine and lithium formate EPR dosimeters and LiF TL-dosimeters – Comparison with Monte Carlo simulations
چکیده انگلیسی

The dose-to-water energy dependence may be defined as the dosimeter reading per absorbed dose to water for a given radiation beam relative to that for 60Co γ rays. The purpose of this work was to review the literature on the dose-to-water energy dependence of lithium formate and alanine EPR dosimeters and LiF:Mg,Ti TL-dosimeters for clinical beam qualities and to compare the findings with Monte Carlo simulations.Monte Carlo simulations of the energy dependence of lithium formate and alanine EPR dosimeters and LiF:Mg,Ti TL-dosimeters were performed using the EGSnrc code. The following common clinical radiation qualities were applied: 4–24 MV photons, 4–20 MeV electrons, 50–200 kVp X-rays, 192Ir γ rays, and 60Co γ rays as the reference.All dosimeter materials showed measured and Monte Carlo simulated energy responses around unity for MV photons, electrons and 192Ir γ rays, except LiF TL-dosimeters which showed an average underresponse of approximately 3% for electrons. For medium energy X-rays (50–200 kVp), LiF displayed an increasing overresponse with decreasing energy to a maximum of about 40% for 50 kVp X-rays. The two EPR dosimeter materials showed decreasing energy response with decreasing X-ray energy, but lithium formate was less dependent on energy than alanine. Comparisons between Monte Carlo simulations and measurements revealed some deviations for medium energy X-rays, which may be due to LET-effects caused by low energy electrons.In conclusion, lithium formate is the dosimeter material with the lowest energy dependence over a wide range of clinically relevant radiation qualities, which clearly is advantageous for accurate dosimetry.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 46, Issue 9, September 2011, Pages 945–951
نویسندگان
, ,