کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2092921 | 1081834 | 2006 | 10 صفحه PDF | دانلود رایگان |

SummaryThe overall objective of this project was to evaluate levels of airborne fungi present after a mold remediation project and determine the effectiveness of this remediation using airborne mold levels to determine the success of these projects. Andersen N6 (viable) and Air-O-Cell (non-viable) sampling techniques were utilized. Both test methodologies demonstrated that levels of mold in the successfully remediated portions of buildings were significantly different (p<0.05) from the levels found in non-complaint and outdoor samples from the same building, respectively. Conversely, levels in unsuccessful remediation projects were not significantly different (p>0.05) to non-complaint and outdoor samples. Both techniques showed high variability in the overall mold levels found between sites; however, the ratios of specific mold groups in each area tested, within the same site, were remarkably similar. The use of either viable or non-viable mold sampling techniques after mold remediation is essential for determining the success of such projects. This project demonstrates the relationship between mold levels and the success of a mold remediation projects, and will assist in the interpretation of data collected at the conclusion of a mold remediation project.
Journal: Microbiological Research - Volume 161, Issue 4, 17 November 2006, Pages 367–376