کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2157789 1090803 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Helical tomotherapy for SIB and hypo-fractionated treatments in lung carcinomas: A 4D Monte Carlo treatment planning study
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی تحقیقات سرطان
پیش نمایش صفحه اول مقاله
Helical tomotherapy for SIB and hypo-fractionated treatments in lung carcinomas: A 4D Monte Carlo treatment planning study
چکیده انگلیسی

PurposeTo evaluate the impact of intra-fraction motion induced by regular breathing on treatment quality for helical tomotherapy treatments.Material and methodsFour patients treated by simultaneous-integrated boost (SIB) and three by hypo-fractionated stereotactic treatments (hypo-fractionated, 18 Gy/fraction) were included. All patients were coached to ensure regular breathing. For the SIB group, the tumor volume was delineated using CT information only (CTVCT) and the boost region was based on PET information (GTVPET, no CTV extension). In the hypo-fractionated group, a GTV based on CT information was contoured. In both groups, ITVs were defined according to 4D data. The PTV included the ITV plus a setup error margin. The treatment was planned using the tomotherapy TPS on 3D CT images. In order to verify the impact of intra-fraction motion and interplay effects, dose calculations were performed using a previously validated Monte Carlo model of tomotherapy (TomoPen): first on the planning 3D CT (“planned dose”) and second, on the 10 phases of the 4D scan. For the latter, two dose distributions, termed “interplay simulated” or “no interplay” were computed with and without beamlet-phase correlation over the 10 phases and combined using deformable dose registration.ResultsIn all cases, DVHs of “interplay simulated” dose distributions complied within 1% of the original clinical objectives used for planning, defined according to ICRU (report 83) and RTOG (trials 0236 and 0618) recommendations, for SIB and hypo-fractionated groups, respectively. For one patient in the hypo-fractionated group, Dmean to the CTVCT was 2.6% and 2.5% higher than “planned” for “interplay simulated” and “no interplay”, respectively.ConclusionFor the patients included in this study, assuming regular breathing, the results showed that interplay of breathing and tomotherapy delivery motions did not affect significantly plan delivery accuracy. Hence, accounting for intra-fraction motion through the definition of an ITV volume was sufficient to ensure tumor coverage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiotherapy and Oncology - Volume 104, Issue 2, August 2012, Pages 173–180
نویسندگان
, , , , , , , , , , ,