کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2157883 1090816 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی تحقیقات سرطان
پیش نمایش صفحه اول مقاله
Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT
چکیده انگلیسی

PurposeVolumetric modulated arc therapy (VMAT), a novel technique, employs a linear accelerator to conduct dynamic modulation rotation radiotherapy. The goal of this study was to compare VMAT with helical tomotherapy (HT) and step-and-shoot intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) patients with regard to the sparing effect on organs at risk (OARs), dosimetric quality, and efficiency of delivery.Materials and methodsTwenty patients with NPC treated by HT were re-planned by VMAT (two arcs) and IMRT (7–9 fields) for dosimetric comparison. The target area received three dose levels (70, 60, and 54 Gy) in 33 fractions using simultaneous integrated boosts technique. The Philips Pinnacle Planning System 9.0 was adopted to design VMAT, using SmartArc as the planning algorithm. For a fair comparison, the planning target volume (PTV) coverage of the 3 plans was normalized to the same level. Dosimetric comparisons between VMAT, HT, and IMRT plans were analyzed to evaluate (1) coverage, homogeneity, and conformity of PTV, (2) sparing of OARs, (3) delivery time, and (4) monitor units (MUs).ResultsThe VMAT, HT, and IMRT plans had similar PTV coverage with an average of 96%. There was no significant difference between VMAT and HT in homogeneity, while the homogeneity indices of VMAT (1.06) and HT (1.06) were better than IMRT plans (1.07, p < 0.05). HT plans provided a better conformity index (1.17) than VMAT (1.28, p = 0.01) and IMRT (1.36, p = 0.02). When compared with IMRT, VMAT and HT had a better sparing effect on brain stem and spinal cord (p < 0.05). The effect of parotid sparing was similar between VMAT (mean = 26.3 Gy) and HT (mean = 27.5 Gy), but better than IMRT (mean = 31.3 Gy, p < 0.01). The delivery time per fraction for VMAT (5.7 min) were much lower than for HT (9.5 min, p < 0.01) and IMRT (9.2 min, p < 0.01).ConclusionsOur results indicate that VMAT provides better sparing of normal tissue, homogeneity, and conformity than IMRT, and shorter delivery time than HT.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiotherapy and Oncology - Volume 104, Issue 3, September 2012, Pages 324–330
نویسندگان
, , , , , , , , , , , ,