کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
235920 465652 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A comparative analysis of particle tracking in a mixer by discrete element method and positron emission particle tracking
ترجمه فارسی عنوان
تجزیه و تحلیل تطبیقی ​​ردیابی ذرات در یک میکسر با استفاده از روش المان گسسته و ردیابی ذرات انتشار پوزیترون
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


• The effect of mixing time on the tracer velocity distribution inside the mixer.
• The effect of multiple tracer on the velocity distribution.
• PEPT experiment not reflecting on the entire particle population.

Characterisation of particle flow using Positron Emission Particle Tracking (PEPT) is based on tracking the position of a single particle in a dynamic system. Recent developments in PEPT have facilitated tracking multiple particles aiming at improvements in data representation. Nevertheless for systems with a wide residence time distribution and/or dead zone, the conditions for getting representative data which could reflect the bulk behaviour of the powders need to be analysed and specified. In the present work, an attempt is made to simulate PEPT experiments for a paddle mixer using Discrete Element Method (DEM), with a view to investigate the effect of increasing the number of tracers on their time-averaged velocity distribution and whether it can represent the data on whole population of particles. The time averaged velocity distribution of the individual tracer particles (resembling simulated PEPT) is obtained and compared with the time averaged data on entire particle population. The DEM results indicate that for the investigated paddle mixer, it takes 251 s for one tracer to travel adequately in all the active space of the system. The instantaneous tracer velocity fluctuates around the average value obtained for all the particles, suggesting that the average tracer velocity is adequately representative of the average particle velocity in the system. The data of the PEPT experiment with one tracer with those of DEM with one tracer are in good agreement; however, DEM simulation suggests that increasing the number of tracers in the paddle mixer system does not influence the average velocity distribution. Furthermore, the velocity for all particles in the DEM shows a smooth distribution with a peak frequency of the velocity distribution that is lower than PEPT and DEM tracer. When tracking a single tracer in DEM or PEPT, it may not be detected to have zero velocity at any instant of time, whilst the data for all particles show that about 0.3% of particles are stagnant.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Powder Technology - Volume 270, Part B, January 2015, Pages 569–574
نویسندگان
, , , , , ,