کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
242607 501881 2015 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance characteristics of cross-flow membrane contactors for liquid desiccant systems
ترجمه فارسی عنوان
ویژگی های عملکرد گیرنده های غشاء متقاطع برای سیستم های تخلیه مایع
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی


• Different types of flat plate membrane contactors developed to eliminate carryover in liquid desiccant systems.
• Two-dimensional steady-state model developed to predict performance of contactors.
• The simulated results are found to be in good agreement with experimental findings.
• Performance of the contactors depends significantly on the membrane characteristics.
• Parametric analysis carried out to select best operating ranges of design parameters.

Membrane based indirect contact liquid desiccant dehumidification technology subsides the serious concern of liquid desiccant droplet carryover observed in conventional direct contact liquid desiccant systems. In the membrane contactor the air and liquid desiccant streams flow in alternate channels in cross-flow arrangement, separated by micro-porous semi-permeable hydrophobic membranes. Only water vapor can pass through the membranes but liquid desiccant cannot permeate. A two-dimensional steady-state mathematical model for semipermeable membrane based indirect contactors as dehumidifiers for liquid desiccant dehumidification applications has been developed. The model can predict the air and desiccant parameters inside the dehumidifier and the outlet parameters for a given input parameters. Five different membrane contactors have been fabricated and series of experiments have been conducted to validate the mathematical model. Aqueous solution of lithium chloride has been used as desiccant. The maximum deviations between experimental and predicted values are within ±10% for outlet specific humidity and outlet enthalpy of air, ±15% deviation in dehumidification effectiveness and ±20% deviation in enthalpy effectiveness. The distributions of major parameters viz. temperature, humidity, concentration, etc., within the contactor have been presented. Parametric analysis has been carried out to study the effects of membrane characteristics, contactor design, fluid flow rates, ambient conditions and desiccant concentration on the performance of the contactors.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 141, 1 March 2015, Pages 1–11