This paper establishes a methodology for the estimation of the primary energy savings of an industrial (sub)-sector and the primary energy savings of the total energy system due to CHP. A primary energy savings indicator within a (sub)-sector and a total primary energy savings indicator are developed which are related with the actual energy use of a (sub)-sector and the way of disposal of the excess CHP energy produced. The methodology is applied in an industrial sub-sector in Greece according to the ‘power match’ and the ‘thermal match’ CHP sizing scenarios; subsequently results are presented and the developed indicators are fully explained. It was found that the primary energy savings indicator of a sub-sector is determined by the efficiencies of the relevant technologies, and the interrelation of the ‘power to heat’ ratio of the CHP technology used and the ‘power to heat’ ratio of the sub-sector examined; the total primary energy savings indicator is determined by the efficiencies of the relevant technologies and the percentage of the CHP energy exported from the sub-sector. The methodology can be utilized for optimum CHP planning.