کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2451059 1109670 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of different devices for predicting the lean meat percentage of pig carcasses
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک دانش تغذیه
پیش نمایش صفحه اول مقاله
Comparison of different devices for predicting the lean meat percentage of pig carcasses
چکیده انگلیسی

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatuses and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n = 77) were fully scanned with X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM had better accuracy than UFOM and VCS2000.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Meat Science - Volume 83, Issue 3, November 2009, Pages 443–446
نویسندگان
, ,