Effect of inlet design on the performance of storage-type domestic electrical water heaters
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Effect of inlet design on the performance of storage-type domestic electrical water heaters
چکیده انگلیسی

The effect of inlet design on the performance of storage-type domestic electrical water heaters (EWHs) was experimentally investigated for energy conservation. Three different side-inlet geometries; namely wedged, perforated, and slotted pipe-inlets; were tested using two 50 L capacity EWHs of aspect ratios 1 and 2 and two discharge rates 5 and 10 L/min. The three inlet designs are successful in promoting good thermal stratification inside the storage tanks of the EWHs. However, the degree of mixing produced by each design is found to have a significant impact on the performance. Thermal performance is quantified in terms of discharge efficiency, extraction efficiency, and fraction of heat recoverable. The results show an excellent performance for the slotted inlet. Although performance measures of perforated inlet are slightly less, the slotted inlet is attractive as it is simpler to manufacture and the extra cost associated with adopting it inside the existing EWH models is justified by the substantial savings in electricity and water consumptions, which ultimately concern the users.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 84, Issue 12, December 2007, Pages 1338–1355