ObjectivesAvalanche victims are subjected to a number of physiological stressors during burial. We simulated avalanche burial to monitor physiological data and determine whether wearing head and face insulation slows cooling rate during snow burial. In addition, we sought to compare 3 different types of temperature measurement methods.MethodsNine subjects underwent 2 burials each, 1 with head and face insulation and 1 without. Burials consisted of a 60-minute burial phase followed by a 60-minute rewarming phase. Temperature was measured via 3 methods: esophageal probe, ingestible capsule, and rectal probe.ResultsCooling and rewarming rates were not statistically different between the 2 testing conditions when measured by the 3 measurement methods. All temperature measurement methods correlated significantly.ConclusionsHead and face insulation did not protect the simulated avalanche victim from faster cooling or rewarming. Because the 3 temperature measurement methods correlated, the ingestible capsule may provide an advantageous noninvasive method for snow burial and future hypothermia studies if interruptions in data transmission can be minimized.
Journal: Wilderness & Environmental Medicine - Volume 26, Issue 1, March 2015, Pages 21–28