Effect of supply/exhaust diffuser configurations on the contaminant distribution in ultra clean environments: Eulerian and Lagrangian approaches
ترجمه فارسی عنوان
تأثیر تنظیمات پخش کننده خروجی / خروجی بر روی توزیع آلودگی در محیط های فوق العاده پاکسازی: رویکردهای اویلر و لاگرانژی
کلمات کلیدی
اتاق تمیز، رویکرد یولر، رویکرد لاگرانژی، ذرات، تنظیمات عرضه / خروجی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی


• A comparative study on different supply/exhaust configurations was studied.
• The E-E and E-L approaches were applied to compare the contaminant distribution.
• Three different supply diffuser configurations were selected for the analysis.
• The ventilation performance of different exhaust grille configurations was compared.
• The variations of concentration in both E-E and E-L approaches are almost the same.

In this research, the airflow pattern and particle dispersion in a contaminated full-scale cleanroom are investigated numerically using both Eulerian and Lagrangian approaches. Three different supply diffuser configurations namely (1) central, (2) horizontal and (3) vertical and three different exhaust grille configurations namely (4) vertical symmetric, (5) asymmetric and (6) horizontal symmetric are selected for the analysis. The presented results reveal that the supply/exhaust openings arrangement has a significant influence on the particulate contaminant dispersion in the cleanrooms. The comparison of the above different supply diffuser configurations shows that the vertical and horizontal supply diffuser configurations lead to a more escaped particles and less deposited particles on the room walls and installed working table in the room than the central one. It is also found that for different exhaust grille arrangements, the performance of the ventilation system in the horizontal symmetric case is higher than asymmetric and vertical symmetric ones. At the same time, it is observed that the variations of contaminant concentration in both Eulerian and Lagrangian approaches are almost the same. The results of the velocity and particle concentration show good agreement with the available experimental data in the literature.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 127, 1 September 2016, Pages 648–657