کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2620642 1135634 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Test-Retest Reliability, Repeatability, and Sensitivity of an Automated Deformation-Controlled Indentation on Pressure Pain Threshold Measurement
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب مکمل و جایگزین
پیش نمایش صفحه اول مقاله
Test-Retest Reliability, Repeatability, and Sensitivity of an Automated Deformation-Controlled Indentation on Pressure Pain Threshold Measurement
چکیده انگلیسی

ObjectiveThe purpose of this study was to construct a computerized deformation-controlled indentation system and compare its test-retest reliability, repeatability, and sensitivity with a manual algometer for pressure pain threshold (PPT) measurements.MethodsPressure pain threshold measurements were made on 16 healthy subjects for 2 sessions on bilateral erector spinae muscles at L1, L3, and L5 spinal levels, consisting of 5 repeated trials each using computerized algometry on one side and manual algometry on the other side. Mean, SD, coefficient of variation, standard error of measurement, minimal detectable change, and intraclass correlation coefficient were calculated for both manual and computerized PPT measurements. Effects of session, level, method, and side on PPT measurements were evaluated using analysis of variance.ResultsManual PPT measurements were significantly larger than computerized PPT measurements (P = .017), and session 2 was significantly larger than session 1 (P = .021). Coefficient of variation, intraclass correlation coefficient, standard error of measurement, and minimal detectable change of the manual and computerized PPT measurements were 10.3%, 0.91, 0.19 kg/cm2, and 0.54 kg/cm2 and 15.6%, 0.87, 0.26 kg/cm2, and 0.73 kg/cm2, respectively.ConclusionsAlthough computerized algometry offers the benefits of eliminating the effects of operator reaction time, operator anticipation, alignment error, and variation in indentation rate on PPT measurements, these results indicate that manual algometry using load-controlled strategy may be better than computerized deformation-controlled algometry in terms of test-retest reliability, repeatability, and sensitivity. Constant load-controlled indentation protocol may be more favorable for PPT measurements. Future computerized instrumentation for PPT measurements should adopt a load-controlled mechanism.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Manipulative and Physiological Therapeutics - Volume 36, Issue 2, February 2013, Pages 84–90
نویسندگان
, , ,