کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
262079 504009 2016 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot Box
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot Box
چکیده انگلیسی


• U-value of an opaque wall has been experimentally evaluated.
• Novelties are the application, comparison and discussion of different approaches.
• Four approaches for the U-value assessment by IR method have been employed.
• Experiments have been performed using a Guarded Hot Box.
• Results have been discussed against different parameters.

The thermal transmittance (U-value) of the vertical opaque building envelope plays a key role for the evaluation of the thermal performance of a structure.In order to speed up the assessment procedure and to investigate wider portions of buildings directly in situ, new methods based on the use of quantitative infrared thermography have been proposed during the last years.Although the studies agree about the influence of the operative conditions, a detailed report, based on measurements effected on a large wall in a controlled environment and at different boundary conditions, is still missing in literature.The aim of this work is to assess the validity of thermographic methods by using different operative conditions in a controlled environment. The results obtained by different IR methods in a Guarded Hot Box have been compared with heat flow meter measurements and theoretical values.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 122, 15 June 2016, Pages 211–221
نویسندگان
, , , , ,