Modeling and performance evaluation of shallow ground water heat pumps in Beijing plain, China
چکیده انگلیسی

The use of groundwater for cooling and heating purposes is of interest from both the economical and the ecological perspective. The groundwater heat pump (GWHP) system utilizes groundwater as alternative renewable and clean energy source for space heating and/or cooling, withdraws water from a production well, passes it through a heat exchanger and discharges the water into an injection well. By utilizing the relatively stable temperature of groundwater, GWHP system can achieve a higher coefficient of performance. Due to the utilization of groundwater stored in the aquifer, the assessment of the hydraulic capacity of the aquifer based on numerical groundwater models is always needed for the optimum design and the efficient performance of GWHP. In this paper, numerical methods of underground heat-water transfer, energy balance method and thermal storage method were presented to calculate the capacity of unit area of shallow groundwater aquifer. The model results indicate that the numerical method, which is based on performance efficiency of GWHP, represents the behaviour of groundwater pumping/recharging processes, and serves better than energy balance method and thermal storage method, in addition it has been proven itself that this method has the advantages of energy saving and environmental protection. The calculated capacity is positively related to aquifer thickness. It is found that it is easy for ground water recharge in alluvial and pluvial fan located at the piedmont, while the calculated capacity is relatively smaller compared with that of south-east plain where it is not easy for groundwater recharge.


► Carrying out a quantitative assessment of groundwater heat pumps.
► Three methods are applied to estimate the load capacity of groundwater heat pumps.
► A numerical model of underground heat transfer is applied in the load capacity assessment of aquifer.
► The results are significant for the use of ground water as a heat source in the north of China.