Placement of the nebulizer before the humidifier during mechanical ventilation: Effect on aerosol delivery
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Placement of the nebulizer before the humidifier during mechanical ventilation: Effect on aerosol delivery
چکیده انگلیسی

BackgroundTherapeutic aerosols are commonly used in mechanically ventilated patients. The position of the nebulizer in the ventilator circuit and the humidification of inhaled gases can influence the efficiency of aerosol delivery. We evaluated the effect of nebulizer position on the pulmonary bioavailability of nebulized ipratropium in ventilated patients without known preexisting respiratory disease.MethodsThe study included 38 mechanically ventilated and sedated patients after open heart surgery. Ipratropium (500 μg) was delivered by an ultrasonic nebulizer. Patients were randomized into 2 groups: the nebulizer positioned before the heat humidification system (group 1, n = 19) or at the end of the inspiratory limb before the Y-piece (group 2, n = 19). The amount of ipratropium in the urine collected during the 4 hours after drug administration was measured by mass spectrometry.ResultsThere were no statistically significant differences in tidal volume or respiratory rate between groups. There were no significant differences between the 2 groups in the amount of drug excreted (group 1 vs 2: 13,237 ± 2313 pg/mL vs 15,529 ± 3204 pg/mL) or in pulmonary bioavailability (.9% ± .1% vs 1.1% ± .2%).ConclusionThe position of the nebulizer in the ventilatory circuit had no effect on the pulmonary bioavailability of ipratropium.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Heart & Lung: The Journal of Acute and Critical Care - Volume 38, Issue 5, September–October 2009, Pages 435–439
نویسندگان
, , , , , ,