Comparative analysis of energy performance between courtyard and atrium in buildings
چکیده انگلیسی

In this paper, the energy performance of a central atrium is investigated and compared with the energy performance of a courtyard with the same geometric proportions. The atrium and the courtyard design used for the analysis are square in plan and surrounded by the building on all four sides. The glazing type and percentage for the courtyard walls and atrium skylight are varied in the analysis. Weather data from four cities representative of climatic conditions of cold, temperate, hot-humid and hot-dry were used. The results show that, in general, the open courtyard building exhibits a better energy performance for the shorter buildings. As the building height increases, however, at some point the enclosed atrium exhibits a better energy performance. This “break even” point for the number of stories depends on different factors like glazing and climate parameters discussed above.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 40, Issue 3, 2008, Pages 209–214