Thermal behaviour of interactive mechanically ventilated double glazed façade: Non-dimensional analysis
چکیده انگلیسی

Non-dimensional analysis is proposed as a method to analyse mechanically ventilated double glazed façade energy performance. The 12 non-dimensional numbers defined, can be used to describe thermal and energy performance of interactive façade designs. A comparison between Nusselt number solved by experimental data and Nusselt calculated by the validated multivariable correlation function is reported in the present paper. Due to its wide validity field the proposed method can be used to analyze thermodynamic performances of glass double-skin façades with mechanical ventilation. Applying it, useful design indications can be derived also by varying some parameters using thermo-physical and climatic data easy to get.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 38, Issue 1, January 2006, Pages 1–7