کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2697206 1143888 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reverse geometry contact lens fitting in corneal scar caused by perforating corneal injuries
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
پیش نمایش صفحه اول مقاله
Reverse geometry contact lens fitting in corneal scar caused by perforating corneal injuries
چکیده انگلیسی

PurposeTo describe a reverse geometry rigid gas permeable (RGP) contact lens fitting in corneal scar caused by perforating corneal injuries with intraocular strange body.MethodsA reverse geometry RGP lens, with large diameter, was empirically fitted in a 38-year-old male patient who had previous open globe injuries due to work accident in right eye. Corneal suture, vitrectomy and lens extraction were performed. Irregular corneal surface with corneal scar in line with the visual axis were found with low uncorrected visual acuity.ResultsSnellen visual acuity improved from counterfinger to 0.8 with high contact lens acceptance, 6–9 h per day of wear. Only three diagnostic contact lenses, in two visits, were necessary. Orbscan simulated fluorescein pattern was different to definitive fluorescein pattern.ConclusionsReverse geometry RGP contact lens, with large diameters, could be a good alternative in irregular corneal surface with corneal scar. Fluorescein pattern analysis could be the proper fitting technique. This fitting could involve less time and fewer visits. Computer-aided fitting was of limited value in these cases.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Contact Lens and Anterior Eye - Volume 30, Issue 1, March 2007, Pages 67–70
نویسندگان
, ,