کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2700699 1565144 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Outcome of posterior chamber phakic intraocular lens procedure to correct myopia
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
پیش نمایش صفحه اول مقاله
Outcome of posterior chamber phakic intraocular lens procedure to correct myopia
چکیده انگلیسی

PurposeTo assess the safety and efficacy of the implantable contact lens (ICL™) to treat myopia.DesignClinical, retrospective, single center, non-randomized case series.ParticipantsSixty-nine eyes of 46 patients with myopia ranging from −3.00 to 25.00 D were included in this study.InterventionImplantation of the ICL™.Main outcome measuresUncorrected Visual Acuity (UCVA), refraction, best spectacle corrected visual acuity (BSCVA), adverse events, operative and postoperative complications, subjective assessment and symptoms.ResultsThe mean follow-up was 12.35 ± 6.13 (SD) months (range, 6 months–32 months). At the last visit, 49.20% of eyes had 20/20 or better UCVA compared to preoperative 20/20 or better BSCVA of 31.9% of eyes; 69.23% of eyes had postoperative UCVA better than or equal to preoperative BSCVA. The mean manifest refractive cylinder was 1.93 ± 1.21 D at baseline and 1.00 ± 0.92 D postoperatively. The mean manifest refraction spherical equivalent (MRSE) was −11.70 ± 4.24 D preoperatively and −0.69 ± 1.13 D postoperatively. A total of 69.8% of eyes were within ±0.5 D of the predicted MRSE; 84.1% were within ±1.0 D, and 88.90% were within ±2.0 D. BSCVA of 20/20 or better was achieved in 64.6% of eyes postoperatively, compared to 31.9% preoperatively. Mean improvement in BSCVA was 1line. One eye (1.5%) lost ⩾2 lines of BSCVA at the last visit, whereas 20% of eyes improved by ⩾2 lines. A total of 56.92% of cases gained ⩾1 line of BSCVA and 4.62% of cases lost ⩾1 line. Four ICL lenses were removed without significant loss of BSCVA, and 2 eyes with clinically significant lens opacities were observed. Four eyes (5.8%) developed a pupillary block the first day postoperatively. One eye (1.4%) developed a hypotony and AC shallowing.ConclusionImplantation of ICL for the correction of myopia was a safe procedure with good visual and refractive results from the early postoperative period to 1 year. Long-term follow-up is required to confirm the long-term safety of this implant.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Saudi Journal of Ophthalmology - Volume 27, Issue 4, October–December 2013, Pages 259–266
نویسندگان
, , , ,