کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2712635 1145119 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accuracy of Ultrasound-Guided and Palpation-Guided Knee Injections By an Experienced and Less-Experienced Injector Using a Superolateral Approach: A Cadaveric Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Accuracy of Ultrasound-Guided and Palpation-Guided Knee Injections By an Experienced and Less-Experienced Injector Using a Superolateral Approach: A Cadaveric Study
چکیده انگلیسی

ObjectivesTo evaluate the accuracy of ultrasound (US)-guided and palpation-guided knee injections by an experienced and a less-experienced clinician with use of a superolateral approach.DesignSingle-blinded, prospective study.SettingAcademic institution procedural skills laboratory.ParticipantsTwenty cadaveric knee specimens without trauma, surgery, or major deformity.InterventionUS-guided and palpation-guided knee injections of colored liquid latex were performed in each specimen by an experienced and a less-experienced clinician with use of a superolateral approach. The order of injections was randomized. The specimens were subsequently dissected by a blinded investigator and assessed for accuracy.Main OutcomesAccuracy was divided into 3 categories: (1) accurate (all of the injectate was within the joint), (2) partially accurate (some of the injectate was within the joint and some was within the periarticular tissues), and (3) inaccurate (none of the injectate was within the joint). The accuracy rates were calculated for each clinician and guidance method.ResultsUS-guided knee injections that used a superolateral approach were 100% accurate for both clinicians. Palpation-guided knee injections that used a superolateral approach were significantly influenced by experience, with the less-experienced investigator demonstrating an accuracy rate of 55% (95% confidence interval = 34%-74%) and the more experienced investigator demonstrating an accuracy rate of 100% (95% confidence interval = 81%-100%).ConclusionsUS-guided knee injections that use a superolateral approach are very accurate in a cadaveric model, whereas the accuracy of palpation-guided knee injections that use the same approach is variable and appears to be significantly influenced by clinician experience. These findings suggest that US guidance should be considered when one performs knee injections with a superolateral approach that require a high degree of accuracy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: PM&R - Volume 3, Issue 6, June 2011, Pages 507–515
نویسندگان
, , , , , ,