کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2741973 1148573 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Compatibility of medications during multi-infusion therapy: A controlled in vitro study on a multilumen infusion device
ترجمه فارسی عنوان
سازگاری داروها در طی چند تزریق درمانی: یک مطالعه آزمایشگاهی بر روی یک دستگاه تزریق چند منظوره
کلمات کلیدی
سیستم های تحویل دارو / ابزار دقیق، تزریق تزریقی ناسازگاریهای مواد مخدر، تست مواد
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
چکیده انگلیسی

ObjectiveDrug incompatibilities can jeopardize the safety and effectiveness of intravenous drug therapies, especially in the field of anaesthesia and intensive care. Patients receive many drugs simultaneously through limited venous accesses. This study was designed to confirm the impact of a multilumen infusion device on the occurrence of known physical drug incompatibilities.Study designIn vitro laboratory work.MethodsTwo infusion devices were studied: a standard single-lumen set and a multilumen infusion access device (Edelvaiss Multiline-8, Doran International). Up to six drugs were infused simultaneously: three acidic solutions of midazolam, amiodarone and dobutamine, and three alkaline solutions of furosemide, pantoprazole and amoxicillin/clavulanate. Saline, Ringer’ solution and 5% dextrose were used as hydration vehicles with an infusion rate initially set at 100 mL/h and with stepwise decreases of 10 mL/h until precipitation. Two methods were used to highlight physical drug compatibility according to the European Pharmacopoeia: visual inspection of the extension set and an obscured-light sub-visible particle count test of infusions. The lowest infusion rate value for vehicle infusion to satisfy the two tests in all trials is reported for each infusion device.ResultsThe standard set did not satisfy the test in 82% of the assessed drug combinations. The Edelvaiss Multiline-8 was able to prevent the occurrence of drug incompatibilities in 49% of the drug combinations tested. This device is therefore advantageous, especially when simultaneously infusing two or four incompatible drugs.ConclusionsInfusion device characteristics have an impact on physical drug incompatibilities. Our results confirm that the Edelvaiss Multiline-8 device prevents physical drug incompatibilities under specified conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Anaesthesia Critical Care & Pain Medicine - Volume 34, Issue 2, April 2015, Pages 83–88
نویسندگان
, , , , , , ,